MCS 2-WAY Non Remote Dampers (2WNR)

Adjustment Instructions MCS 2-Way Non Remote Dampers

Beginning settings and how to adjust compression and rebound on your MCS 2-Way Non Remote dampers.

Beginning settings

Front and rear:

|  Compression="4"     Rebound="8"

Values are clicks from 0 (fully soft). Run the 2WNR in the rebound position, with the knob down.

General information

  • We recommend running the MCS 2WNR damper in the rebound position, with the adjuster locked in the lower position.
  • Do not use impact tools to install pin mount top nuts.
  • The 8 mm brass hex nut at the top of the damper is the compression and rebound adjuster. Do not use it to hold the shaft while installing the first top nut. Install the first top nut onto your mount and snug it with a wrench or socket, then cinch it with a quick jerking motion or a tap from a plastic hammer. This is more than enough to secure the shaft to the top mount. Install the second nut and tighten it against the first. Holding the first top nut with a tappet wrench (thin wrench) makes this easier.
  • When fitting the adjuster knob onto the 8 mm brass hex nut, make sure it clears all body components.

Adjustment instructions

MCS 2-Way Non Remote dampers are independently adjustable in rebound (extension) and bump (compression) with a single knob. With the knob in the upper position it adjusts compression; in the lower position it adjusts rebound. The release button in the center of the knob releases it from the lower position to the upper position.

  • Knob up: compression
  • Knob down: rebound (recommended running position)

‍


Compression adjustment

Press the center release button to bring the knob up from the lower (rebound) position to the upper (compression) position.

Range: 15 positions (14 clicks). 0 = softest, 14 = stiffest. Arrows on top of the knob show the firmer and softer directions.

  • Clockwise (−) softens compression damping.
  • Counter-clockwise (+) stiffens compression damping.

When fitting the damper for the first time, set compression to 4 clicks from 0. Press the center release button to bring the knob to the upper position, then turn it clockwise until it stops, backing off slightly if needed so it settles into a detent.

Once it stops turning, DO NOT force it any further. This is the “0” position. From here, turn the knob counter-clockwise 4 clicks. Compression is now set.

‍



Rebound adjustment

Rebound is adjusted with the knob in the lower position. If the knob is still up, push it down until it snaps into place.

Range: 19 positions (18 clicks). 0 = softest, 18 = stiffest.

  • Clockwise (−) softens rebound (extension) damping.
  • Counter-clockwise (+) stiffens rebound (extension) damping.

When fitting the damper for the first time, set rebound to 8 clicks from 0. With the knob in the lower position, turn it clockwise until it stops, backing off slightly if needed so it settles into a detent.

Once it stops turning, DO NOT force it any further. This is the “0” position. From here, turn the knob counter-clockwise 8 clicks. Rebound is now set.

‍

Recommended Settings

Run The 2WNR Dampers inRebound Position = Lower Position

Need help?

Call us toll free on 866-391-1091 or on 770-220-7940, or email info@motioncontrolsuspension.com.

Download the instructions

Get the full instructions as a PDF to keep with your dampers or print for the workshop.

See other instructions

Compare
1WNR

A single adjustable damper that over delivers.

See Instructions
Compare
2WR

Remote reservoir performance with large blow off valves for stronger high speed control and improved compliance.